LASER DISTANCE METER/INFRARED THERMOMETER COMBO KIT, 414D/62 MAX +

The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy to use 414D Laser Distance Meter has everything you need to configure layout and to troubleshoot electrical/HVAC problems quickly. Use the IR thermometer to test for overheating in electrical devices and HVAC components, and use the laser distance meter to determine distance, area, and volume for space configuration.

Product Description

Features

The 414D reduces errors, saves time and money.
  • The most advanced laser technology for distance measurement.
  • Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in).
  • Quick calculation of area (square feet/meters) and volume.
  • Pythagoras function indirectly measures height via two other measurements.
  • Stores up to five measurement results.
  • Battery life of 3000 measurements with automatic shut-off feature.
Fluke 62 MAX+. Small in size. Big on toughness.
  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.


Specifications

Fluke 414D Laser Distance Meter
Distance Measurement
Typical Measuring Tolerance[1]
± 2.0 mm [3]
Maximum Measuring Tolerance[2]
± 3.0 mm [3]
Range at Leica target plate GZM26
50 m / 165 ft
Typical Range[1]
40 m / 130 ft
Range at unfavorable condition[4]
35 m / 115 ft
Smallest unit displayed
1 mm / 1/16 in
∅ laser point at distances
6 /30 / 60 mm
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5]
No
Measuring tolerance to housing[5]
No
Range
No
General
Laser class
2
Laser type
635 nm, <1 mW
Protection class
IP40
Automatic laser off
After 90 seconds
Automatic power off
after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03
Up to 3,000
measurements
Size (H X W X L)
116mm Length
53mm Width
33mm Depth
Weight (with batteries)
113 g
Temperature range: Storage Operation
-25 °C to +70°C
(-13 °F to +158 °F) 0 °C to +40 °C
(32 °F to +104 °F)
Calibration cycle
Not applicable
Maximum altitude
3000 m
Maximum relative humidity
85% at 20 °F to 120°F
(-7 °C to 50 °C)
Safety
IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC
EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10’000 lux and 30’000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.
Fluke 62 MAX+ Infrared Thermometer
Specifications
Temperature Range
-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX+
<300 ms (95% of reading)
Spectral Response
8 to 14 microns
Emissivity
0.10 to 1.00
Optical Resolution
12:1 (calculated at 90% energy)
Display Resolution
0.1 °C (0.2 °F)
Repeatability of Readings
±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
AA battery
Battery Life
8 hours with laser and backlight on
Physical Specifications
Weight
255 g (8.99 oz)
 
Size
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
 
Operating Temperature
0 °C to 50 °C (32 °F to 122 °F)
 
Storage Temperature
-20 °C to 60 °C (-4 °F to 140 °F), (without battery)
 
Operating Humidity
10 % to 90 % RH non-condensing at 30 °C (86 °F)
 
Operating Altitude
2000 meters above mean sea level
 
Storage Altitude
12,000 meters above mean sea level
 
IP Rating
IP 54 per IEC 60529
 
Drop Test
3 meters
 
Vibration and Shock
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
 
EMC
EN 61326-1:2006 EN 61326-2:2006
Standards and Agency Approval
Compliance
 EN/IEC 61010-1: 2001
 
Laser Safety
FDA and EN 60825-1 Class II
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Model Name
Description
Fluke 414D/62 MAX+ Kit
Includes:
  • Fluke 414D Laser Distance Meter
  • Fluke 62 MAX+ IR Thermometer

Reviews

There are no reviews yet.

Be the first to review “LASER DISTANCE METER/INFRARED THERMOMETER COMBO KIT, 414D/62 MAX +”